2 Channel Dry Contact Relays NO NC Outputs Radio Control Receiver


Price: US $18.00

  • Model: 0020063 (S2U-DC-ANT3)

Please Choose:











Qty:    



 
 
Manual

Package Include:
1 x Receiver: S2U-DC-ANT3
1 x User manual

Feature:
Application: It can be used in industry automation, agriculture automation and home automation, such as factory, house, farm, pasture, vehicle, ship, offshore operation, aerial vehicle, field call, etc. It can remote control equipments on land, water and air, such as remote control lights, sirens, locks, motors, fans, winches, blinds, linear actuators, doors, windows, electric solenoid valves, security alarm, business signs and various devices.
Wireless control, easy to install.
Power Supply: Four working voltage versions, DC 6V, 9V, 12V, 24V.
Relay Output: This receiver is relay output, it can be used to operate both DC and AC equipments. The terminals are NO / NC (normally open / normally closed), which serves as a switch. That means you should also connect a separate power supply to equipments.
Each channel can work at maximum current 10A.
With external telescopic antenna, the receiver have a farther working range.
You can control the equipments by using the receiver with transmitter (remote control) from any place within a reliable distance.
Wireless RF signal can pass through walls, floors, doors or windows.
With reverse power protection and over current protection.
Reliable control: The code has thousands of different combinations, and the receiver only works with the transmitter which use the same code.
One/several transmitters can control one/several receivers simultaneously.
You can use two or more units in the same place.

Receiver Parameters:
Model No.: S2U-DC06 / S2U-DC09 / S2U-DC12 / S2U-DC24
Power Supply (Operating Voltage): DC6V (S2U-DC06), DC12V±1V (S2U-DC12), DC9V±1V (S2U-DC09), DC24V±2V (S2U-DC24)
Output: Relay output (Normally open and normally closed)
Working Voltage Range of Relay: AC110~240V or DC0~28V
Wire range for the terminals: 22-14 AWG
Working Frequency: 433.92MHz
Channel: 2 CH
Control Modes: Self-locking, Momentary, Interlocking, Momentary + Self-locking
Static Current: ≤6mA
Maximum Working Current: 10A / each channel
Operating Temperature: -20 ° C to +70 ° C
PCB size: 67mm x 50mm x 18mm
Case size: 75mm x 54mm x 27mm

Matching Transmitters:
The receiver can work with different transmitters, such as model C-2/C-3 (100M), CWB-2/CWB-3 (50M, waterproof), or CB-2/CB-3 (1000M) etc.
When you set the receiver in Self-locking or Momentary mode, it should work with two buttons transmitter, such as model C-2 (100M), CWB-2 (50M, waterproof), or CB-2 (1000M) etc. When you set the receiver in Interlocking mode, it should work with three buttons transmitter, such as model C-3 (100M), CWB-3 (50M, waterproof), or CB-3 (1000M) etc.

Working Range:
With a transmitter (such as C-2) to form a complete set, the maximum working distance can reach 100M in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this maximum working distance.
If you want to have a further working range, you can use a powerful transmitter, such as CB-2 or CB-3 transmitters.

Usage (with the transmitter C-2 or C-3):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals B and C are Normally Open; Terminals A and B are Normally Closed.

Wiring:
If you want to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +” of INPUT, and connect the negative pole of DC power supply to terminal “N / -” of INPUT.
2) Connect terminal B to the positive pole of DC power supply, connect terminal C to the positive pole of DC lamp, and connect the negative pole of DC lamp to the negative pole of DC power supply.

If you want to control an AC 120V or 220V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +” of INPUT, and connect the negative pole of DC power supply to terminal “N / -” of INPUT.
2) Connect terminal B to the live wire of AC power supply, connect terminal C to one side of AC lamp, and connect another side of AC lamp to the neutral wire of AC power supply.

Setting different control modes:
We have set the receiver as Self-locking control mode before delivery. If you want to use other control modes, do as following operation:

1) Setting Self-locking mode: Only connect Jumper-2.
Mode Self-locking (working with transmitter C-2): Press -> On; Press again -> Off.
Press button A of the transmitter: The relay 1 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 1 is turned on.
Press button A again: The relay 1 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 1 is turned off.
Press button B of the transmitter: The relay 2 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 2 is turned on.
Press button B again: The relay 2 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 2 is turned off.

2) Setting Momentary mode: Only connect Jumper-1.
Mode Momentary (working with transmitter C-2): Press and hold -> On; Release -> Off.
Press and hold button A of the transmitter: The relay 1 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 1 is turned on.
Release button A: The relay 1 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 1 is turned off.
Press and hold button B of the transmitter: The relay 2 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 2 is turned on.
Release button B: The relay 2 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 2 is turned off.

3) Setting Interlocking mode: Disconnect Jumper-1 and Jumper-2.
Mode Interlocking (working with transmitter C-3): Press -> On; Press another button -> Off.
Press button C: The relay 1 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 1 is turned on. The relay 2 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 2 is turned off.
Press button B: The relay 2 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 2 is turned on. The relay 1 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 1 is turned off.
Press button A: The relay 1 & 2 are deactivated (disconnect B and C, connect A and B), and two lamps are turned off.

4) Setting Mixed mode (Momentary + Self-locking): Connect Jumper-1 and Jumper-2.
Mode Momentary for channel 1 (working with transmitter C-2): Press and hold -> On; Release -> Off.
Press and hold button 1 of the transmitter: The relay 1 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 1 is turned on.
Release button 1: The relay 1 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 1 is turned off.

Mode Self-locking for channel 2 (working with transmitter C-2): Press -> On; Press again -> Off.
Press button 2 of the transmitter: The relay 2 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 2 is turned on.
Press button 2 again: The relay 2 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 2 is turned off.
 