Qty:
Package Include:
1×Reciver S4PU-DC-ANT3
1×User Manual
Feature:
Application: It can be used in industry automation, agriculture automation
and home automation, such as factory, house, farm, pasture, vehicle, ship,
offshore operation, aerial vehicle, field call, etc. It can remote control
equipments on land, water and air, such as remote control lights, sirens, locks,
motors, fans, winches, blinds, linear actuators, doors, windows, electric
solenoid valves, security alarm, business signs and various devices.
Wireless remote control, easy to install.
Super long working range, with a transmitter to form a complete set, the working
distance can reach 2000m in an open ground.
Waterproof: The receiver has waterproof case and waterproof connector, it can be
installed outdoors.
Power Supply: Four working voltage versions, DC 6V, 9V, 12V, 24V.
Relay Output: This receiver is relay output, it can be used to operate both DC
and AC equipments. The terminals are NO / NC (normally open / normally closed),
which serves as a switch. That means you should also connect a separate power
supply to equipments.
High Power: Each channel can work at maximum current 30A.
With wired control terminals: You can connect sensors, limit switches, manual
switches or external devices to control the receiver.
With external telescopic antenna, the receiver have a further working range.
You can control the equipments by using the receiver with transmitter (remote
control) from any place within a reliable distance.
Wireless RF signal can pass through walls, floors, doors or windows.
With characteristics of reverse power protection and over current protection.
Reliable control: The code has thousands of different combinations, and the
receiver only works with the transmitter which use the same code.
One/several transmitters can control one/several receivers simultaneously.
You can use two or more units in the same place.
Receiver parameters:
Model No.: S4PU-DC06-ANT3 / S4PU-DC09-ANT3 / S4PU-DC12-ANT3 / S4PU-DC24-ANT3
Power Supply (Operating Voltage): DC6V (S4PU-DC06-ANT3), DC9V±1V
(S4PU-DC09-ANT3), DC12V±1V (S4PU-DC12-ANT3), DC24V±2V (S4PU-DC24-ANT3)
Output: Relay output (Normally open and normally closed)
4 Control Modes: Self-locking, Momentary, Interlocking, Momentary + Self-locking
Working Frequency: 433.92MHz
Maximum Working Current: 30A / each channel
Static Current: ≤6mA
Operating Temperature: -20 ° C to +70 ° C
Wire range for the terminals: 22-12AWG
PCB size: 170mm x 109mm x 18mm
Case size: 200mm x 120mm x 53mm
Matching Transmitters:
The receiver can work with different transmitters, such as model CWB-4 (50M,
waterproof), C-4 (100M) or CB-4 (1000M) etc.
Working Range:
With a transmitter (such as CWB-4) to form a complete set, the maximum
working distance can reach 50M in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an
open ground, no barriers, no any interference. But in the practice, it will be
hindered by trees, walls or other constructions, and will be interfered by other
wireless signals. Therefore, the actual distance may not reach this maximum
working distance.
If you want to have a further working range, you can use a powerful transmitter,
such as CB-4 transmitters.
Usage (with the transmitter CWB-4):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of
relay output terminals: Terminals B and C are Normally Open; Terminals A and B
are Normally Closed.
Wiring:
1) If you want to control a DC 12V lamp, do as following:
1.1 Connect the positive pole of DC power supply to terminal “L / +”, and
connect the negative pole of DC power supply to terminal “N / -”.
1.2 Connect terminal B to the positive pole of DC power supply, connect terminal
A to the positive pole of DC lamp, and connect the negative pole of DC lamp to
the negative pole of DC power supply.
2) If you want to control an AC 220V lamp, do as following:
2.1 Connect the positive pole of DC power supply to terminal “L / +”, and
connect the negative pole of DC power supply to terminal “N / -”.
2.2 Connect terminal B to the live wire of AC power supply, connect terminal A
to one side of AC lamp, and connect another side of AC lamp to the neutral wire
of AC power supply.
Setting different control modes:
We have set the receiver in toggle mode before delivery, if you want to use
other modes, do as following operation.
Setting control mode Latched: Disconnect Jumper-1 and Jumper-2.
Control mode Latched (Channel A, B, C, D): Press -> On, other relays Off; Press
other button -> Off.
Press button A: The relay 1 is activated (connect A and B, disconnect A and C),
and the lamp 1 is turned on.
Other relays are deactivated (disconnect A and B, connect A and C), and other
lamps are turned off.
Press button B: The relay 2 is activated (connect A and B, disconnect A and C),
and the lamp 2 is turned on.
Other relays are deactivated (disconnect A and B, connect A and C), and other
lamps are turned off.
Press button C: The relay 3 is activated (connect A and B, disconnect A and C),
and the lamp 3 is turned on.
Other relays are deactivated (disconnect A and B, connect A and C), and other
lamps are turned off.
Press button D: The relay 4 is activated (connect A and B, disconnect A and C),
and the lamp 4 is turned on.
Other relays are deactivated (disconnect A and B, connect A and C), and other
lamps are turned off.
Setting control mode Momentary: Only connect Jumper-1.
Control mode Momentary (Channel A, B, C, D): Press and hold -> On; Release ->
Off.
Press and hold button A: The relay 1 is activated (connect A and B, disconnect A
and C), and the lamp 1 is turned on.
Release button A: The relay 1 is deactivated (disconnect A and B, connect A and
C), and the lamp 1 is turned off.
Press and hold button B: The relay 2 is activated (connect A and B, disconnect A
and C), and the lamp 2 is turned on.
Release button B: The relay 2 is deactivated (disconnect A and B, connect A and
C), and the lamp 2 is turned off.
Press and hold button C: The relay 3 is activated (connect A and B, disconnect A
and C), and the lamp 3 is turned on.
Release button C: The relay 3 is deactivated (disconnect A and B, connect A and
C), and the lamp 3 is turned off.
Press and hold button D: The relay 4 is activated (connect A and B, disconnect A
and C), and the lamp 4 is turned on.
Release button D: The relay 4 is deactivated (disconnect A and B, connect A and
C), and the lamp 4 is turned off.
Setting control mode Toggle: Only connect Jumper-2.
Control mode Toggle (Channel A, B, C, D): Press -> On; Press again -> Off.
Press button A: The relay 1 is activated (connect A and B, disconnect A and C),
and the lamp 1 is turned on.
Press button A again: The relay 1 is deactivated (disconnect A and B, connect A
and C), and the lamp 1 is turned off.
Press button B: The relay 2 is activated (connect A and B, disconnect A and C),
and the lamp 2 is turned on.
Press button B again: The relay 2 is deactivated (disconnect A and B, connect A
and C), and the lamp 2 is turned off.
Press button C: The relay 3 is activated (connect A and B, disconnect A and C),
and the lamp 3 is turned on.
Press button C again: The relay 3 is deactivated (disconnect A and B, connect A
and C), and the lamp 3 is turned off.
Press button D: The relay 4 is activated (connect A and B, disconnect A and C),
and the lamp 4 is turned on.
Press button D again: The relay 4 is deactivated (disconnect A and B, connect A
and C), and the lamp 4 is turned off.
Setting control mode Momentary + Toggle: Connect Jumper-1 and Jumper-2.
Control mode Momentary (Channel A, B): Press and hold -> On; Release -> Off.
Press and hold button A: The relay 1 is activated (connect A and B, disconnect A
and C), and the lamp 1 is turned on.
Release button A: The relay 1 is deactivated (disconnect A and B, connect A and
C), and the lamp 1 is turned off.
Press and hold button B: The relay 2 is activated (connect A and B, disconnect A
and C), and the lamp2 is turned on.
Release button B: The relay 2 is deactivated (disconnect A and B, connect A and
C), and the lamp 2 is turned off.
Control mode Toggle (Channel C, D): Press -> On; Press again -> Off.
Press button C: The relay 3 is activated (connect A and B, disconnect A and C),
and the lamp 3 is turned on.
Press button C again: The relay 3 is deactivated (disconnect A and B, connect A
and C), and the lamp 3 is turned off.
Press button D: The relay 4 is activated (connect A and B, disconnect A and C),
and the lamp 4 is turned on.
Press button D again: The relay 4 is deactivated (disconnect A and B, connect A
and C), and the lamp 4 is turned off.
Wired control terminals:
The receiver has wired control terminals, and you can connect external devices,
sensors, or manual switches to the receiver's manual terminals, then use them to
trigger the receiver.
1) By low level signal:
You can connect external devices (with low level output signal) to trigger the
receiver.
When the external device outputs low level signal to terminal “COM” and “Signal
1“, Relay1 is activated
When the external device outputs low level signal to terminal “COM” and “Signal
2“, Relay2 is activated
When the external device outputs low level signal to terminal “COM” and “Signal
3“, Relay3 is activated
When the external device outputs low level signal to terminal “COM” and “Signal
4“, Relay4 is activated
2) By NO/NC contact:
You can connect manual switches (with NO/NC contact) to trigger the receiver.
When connect terminals “Signal 1” and “Com”, Relay1 is activated. And when
disconnect “Signal 1” and “Com”, Relay1 is deactivated.
When connect terminals “Signal 2” and “Com”, Relay2 is activated. And when
disconnect “Signal 2” and “Com”, Realy2 is deactivated.
When connect terminals “Signal 3” and “Com”, Realy3 is activated. And when
disconnect “Signal 3” and “Com”, Realy3 is deactivated.
When connect terminals “Signal 4” and “Com”, Realy4 is activated. And when
disconnect “Signal 4” and “Com”, Realy4 is deactivated.