Log In     My Account       Your cart is empty.     SKYPE

Currencies:
     English  French  


Home >>  Delay Function Remote Kits >>  1CH DC Power Remote Kits >>  Wireless Water Leak Leakage Sensor Detector System With Transmitter & Receiver

Stay In Touch

Wireless Water Leak Leakage Sensor Detector System With Transmitter & Receiver


Price: US $58.00

Add to Cart:    Write Review

  • Model: 0020719

Please Choose:























Feature:
Wireless control, easy to install
Setting delay time from 0 to 99 seconds.
Control Lights, Motors, Fans, electrically operated Doors/Locks/Windows/Blinds/Cars or Other Appliances with voltage AC110~240V or DC0~28V.
You can turn on/off the receiver with transmitter (remote control) from any place within a reliable distance; the wireless RF signal can pass through walls, floors and doors.
With characteristics of reverse power protection.
Use an 8-bit microcontroller with low-power and high-speed CMOS technology.
Reliable control: The transmitter (Encoding) and the receiver (Decoding) use an 8-bit code.
One/ several transmitters can control one/ several receivers simultaneously.
If you use two or more receivers in the same place, you can set them with different codes.
Transmitting Frequency: 315MHz / 433MHz

Receiver:
Model No.: S1UD-DC06 / S1UD-DC09 / S1UD-DC12 / S1UD-DC24
Channel: 1 CH
Control Modes: Toggle, Momentary, Latched
Delay time: 0~99 seconds
Coding Type: Fixed code or Learning code
Coding Setting: By learning
Power Supply (Operating Voltage): DC6V (S1UD-DC06), DC12V±1V (S1UD-DC12), DC9V±1V (S1UD-DC09), DC24V±1V (S1UD-DC24)
Working Voltage Range of Relay: AC110~240V or DC0~28V
Output: Relay output (Normally open and normally closed)
Maximum Working Current of Relay: 7A
PCB Size: 45mm x 30mm x 15mm
Case Size: 50mm x 35mm x 23mm
Receiver Sensitivity:-114dbm
Static Current: ≤10mA

Detector:
Model No.: 0025003
Power supply: 12V (1 x 23A -12V battery, can be used for 12 months)
Operating Current: 100mA 
Static Current: ≤6mA
Operating Frequency: 315Mhz / 433Mhz
Transmitting Distance: 500m / 1500ft (theoretically) 
The distance of 500m is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be exposed to some interference by other signals. Therefore, the actual distance may or may not reach 500m.
If you stretches the telescopic antenna, it can have a further working range.
Modulation Mode: ASK
Operating Temperature: 0~50°C (32F~122F)
Unit Size: 115mm x 59mm x 35mm

Usage:
Initial state: Terminals A, B = Normally Closed; Terminals B, C = Normally Open.
Connect device to terminal “B & C”; connect power supply to terminal “+” and “-”.
Setting different control modes (We have set the receiver as Toggle control mode before delivery. If you want to use other control modes, do as following operation):

Setting control mode Toggle: Connect Jumper-2 and Jumper-3.
Control mode Toggle: Press -> On; Press again -> Off.
Press button 1: Turn on the relay (connect B and C, disconnect A and B)
Press button 1 again: Turn off the relay (disconnect B and C, connect A and B)
If you set delay time, such as 30 seconds:
Press button 1: Turn on the relay (connect B and C, disconnect A and B)
After 30 seconds, Turn off the relay automatically (disconnect B and C, connect A and B). Or press button 1 again within 30 seconds: Turn off the relay immediately.

Setting control mode Momentary: Disconnect Jumper.
Control mode Momentary: Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on the relay (connect B and C, disconnect A and B)
Release button 1: Turn off the relay (disconnect B and C, connect A and B)
If you set delay time, such as 20 seconds:
Press and hold button 1: Turn on the relay (connect B and C, disconnect A and B)
After 20 seconds, Turn off the relay automatically (disconnect B and C, connect A and B). And the relay couldn’t be turned off by pressing any button within 20 seconds.

Setting control mode Latched: Connect Jumper-1 and Jumper-2.
Control mode Latched: Press -> On, other relays Off; Press another button -> Off.
Press button 1: Turn on the relay (connect B and C, disconnect A and B)
Press button 2: Turn off the relay (disconnect B and C, connect A and B)
If you set delay time, such as 10 seconds:
Press button 1: Turn on the relay (connect B and C, disconnect A and B)
After 10 seconds, Turn off the relay automatically (disconnect B and C, connect A and B). Or press button 2 within 10 seconds: Turn off the relay immediately.

Delay time setting function:
Press the setting button, the LED off, that means enter into the delay time setting mode. 
Then you can set delay time through pressing the learn button. Press the learn button, LED will flash once, that means the delay time increase 1 seconds, if you want to delay 30 seconds, you need to press the learn button with 30 times.
You can set longest delay time to 99 seconds.
Press the setting button again, the delay time what you have set will be preserved forever even if you turn off power. After the delay time is preserved by the system, LED will flash 3 times, the system will quit the delay time setting mode.
For example, when you use this receiver to control one lamp, and you already set 30 seconds delay time, you can press button 1 to turn on the lamp, and the lamp will turn off automatically after 30 seconds. If you don’t need the delay function, you should clear the delay time.

Clear delay time:
If you don’t want to set the delay time, you can operate as following:
Press the setting button and enter into the delay time setting mode, the delay time what you have set will be cleared automatically.
Press the setting button again, LED will flash 3 times, the system will quit the delay time setting mode.

Package Include:
 1 x Receiver: 0020044 (
S1UD-DC12)
 1 x Water leak detector (0025003)
 1 x User manual

Download the User Manual: Wireless Receiver, Water Leak Detector
Ask A Question
* Required information

*
*
hikc
*